Product Details:
|
Wastewater Discharge Index: | COD<20ppm | NOx Emission Concentration: | <50mg/Nm³ |
---|---|---|---|
NOx Emission Process: | Staged Combustion + Flue Gas Recirculation | Rated Steam Pressure: | 4.2 MPa |
Rated Steam Temperature: | 420°C | Feedwater Temperature: | 102°C |
Delivery Time: | 2-6months | Warranty: | 1 Year |
HS Code: | 8402190000 | ||
Highlight: | low nitrogen water tube boiler,low nitrogen water tube steam boiler,102°c water tube boiler |
Low Nitrogen Water Tube Boiler Environmental Compliance Low-Carbon Transformation
Overview:
The modular water tube boiler integrates a closed-loop water treatment system (using reverse osmosis and condensate reuse technology to achieve zero wastewater discharge), a low-nitrogen combustion adaptation design (controls pollutant emissions and is compatible with subsequent desulfurization and denitrification modifications), and an ISO50001 energy management system certification (supports quantitative management of carbon emission reduction), forming a thermal solution that is both environmentally compliant and adaptable to low-carbon transformation.
Product Image:
Product Introduction:
The modular water tube boiler achieves zero wastewater discharge (COD < 20ppm) through a closed-loop water treatment system (reverse osmosis + condensate reuse technology), meeting the EU BAT standard; it adopts a low-nitrogen combustion adaptation design (NOx emissions < 50mg/Nm³), which is compatible with the refinery's future desulfurization and denitrification transformation; it has obtained the ISO50001 energy management system certification, and the carbon emission reduction can be included in the company's ESG report, helping the petrochemical industry's low-carbon transformation.
Technical Specifications:
Parameter | Specification |
Wastewater discharge index |
COD<20ppm |
NOx emission concentration |
<50mg/Nm³ |
NOx emission process |
staged combustion + flue gas recirculation |
Compatibility |
adapt to the future desulfurization and denitrification system upgrade requirements |
Rated Steam Pressure | 4.2 MPa |
Rated Steam Temperature | 420°C |
Feedwater Temperature | 102°C |
Flue Gas Outlet Temperature | 115°C |
Advantages:
The modular water tube boiler achieves wastewater COD emissions of less than 20ppm through a closed-loop water treatment system (reverse osmosis + condensate reuse technology), approaching zero pollution; it is equipped with a low-nitrogen combustion adaptation design (staged combustion + flue gas recirculation technology) to ensure that the NOx emission concentration is stable at less than 50mg/Nm³, compatible with future desulfurization and denitrification upgrade needs; combined with the ISO50001 energy management system certification, the carbon emission reduction is accurately measured and incorporated into the company's ESG reporting framework, providing a green thermal solution with zero emissions, ultra-low nitrogen environmental protection, and traceable carbon footprint for high-emission scenarios such as refining and chemical industry, helping companies cope with compliance challenges such as carbon tariffs and environmental audits, and accelerating the low-carbon transformation process.
R&D and Production:
Ruiding has established the jiangsu province clean incineration resource engineering technology center and the key laboratory of the JICUI-Ruidings joint innovation center.
This laboratory is equipped with advanced detection equipment such as ICP inductively coupled plasma emission spectrometry, atomic absorption spectrophotometry, atomic fluorescence spectrophotometry, high-temperature combustion ion chromatography analyzer, high-temperature combustion rate analyzer, and rapid equilibrium flash point tester. it possesses capabilities for heavy metal analysis, elemental analysis, off-gas calorific value analysis, ash melting point detection, incineration boiler water quality testing, sewage analysis, and volatile waste analysis, etc.
Related Products:
Main Clients:
Company Introduction:
Ruiding is expertized in the engineering, fabrication, construction, commissioning service of industrial waste combustion treatment system including thermal oxidizer (also referred to as incinerator), heat recovery system (boiler), pressurized vessel, flue gas treatment system (DeSOX, DeNOx) and plate heat exchanger, etc.
Ruiding has been authorized with the Environmental Protection Engineering Class 2 (waste gas, waste liquid, waste solid treatment) EPC certificate, ASME Certificate, Class A boiler manufacturing license, Class A boiler installation and Revamping & Maintenance certificate, A2 designing and manufacturing certificate for press vessel, GC1, GC2 press pipeline designing & construction certificate.
Ruiding covers a building area of over 250,000 square meters and has nearly 300 professional and technical staffs. We have completed over 500 engineering projects, spread across various domestic and international industries, with a significant market share in the petrochemical industry.
Faq:
1. What is the company's main business?
Focus on the R&D, design, production, installation and commissioning of industrial three wastes (waste gas/waste liquid/solid waste) incineration treatment equipment and special boilers, and provide supporting equipment (such as heat exchangers, sludge dryers, etc.) .
2. Do you have industry qualification certification?
The company has now passed the quality, environment, occupational health, and occupational hygiene and safety management system certifications, and has the second-level qualification for environmental protection engineering contracting, Class B special environmental engineering design, Class A boiler manufacturing qualification, Class A boiler installation, inspection and maintenance certificate, A2 pressure vessel design and manufacturing certificate, GC1, GC2 pressure pipeline design and installation certificate, and Class A environmental pollution control (waste, waste gas, waste liquid) qualification certificate.
3. What are the core products?
(1) Waste gas incinerator:
Regenerative thermal oxidation furnace (RTO), regenerative catalytic oxidation furnace (RC0), catalytic oxidation furnace (C0), high temperature thermal incinerator (T0), catalytic denitrification furnace (SCR)
(2) Waste liquid incinerator:
Organic waste liquid incinerator, salt-containing waste liquid incinerator, heavy component residue incinerator
(3) Solid incinerator:
Combined rotary kiln incinerator, gas-controlled pyrolysis incinerator, fluidized bed incinerator, step-type incinerator
(4) A-level boiler:
Modular waste heat boiler, tunnel waste heat boiler, furnace-boiler integrated incineration boiler, large cavity membrane wall boiler, fire tube boiler
(5) Plate heat exchanger:
Fully welded pressure plate heat exchanger, high-efficiency vortex tube heat exchanger, high-efficiency spiral tube heat exchanger
(6) Incineration auxiliary machine:
Sludge dryer, customized burner, solid waste crusher, VOC catalyst
4. In what aspects are the technical advantages reflected? Have you ever had experience in cross-border cooperation?
We have 29 patented technologies, covering the fields of incinerator structure optimization, heat recovery, etc. The company has a first-class design team in China, which has mastered the incinerator technology and is familiar with the operation of incinerators. The designers have a solid theoretical foundation and rich design and practical experience. During the design process, they combine the operation of advanced devices at home and abroad to carry out process and structural design. The design response is fast, and the plan can be modified in time according to the buyer's requirements, and optimization suggestions can be made according to the buyer's data and processes.
5. What does the service scope include?
We provide full-process services from project consultation, scheme design, equipment manufacturing to installation and commissioning, and support pressure pipeline and boiler renovation.
6. Are there any successful cases for reference?
It has served multiple industries including petroleum, chemical, pharmaceutical, and solid waste disposal. Typical cases include organic waste gas RTO system, chemical waste liquid incineration project, etc.
7. How to obtain cooperation or quotation?
You can submit your needs through the official website online form, or contact directly:
Tel: +86 15606162805 ; +86 0510-87418884
Email: ruiding@rdee.com.cn
Address: Xinzhuang Industrial Concentration Zone, Yixing City, Jiangsu Province, China.
8. Is there any international business cooperation?
Holding the independent import and export rights, we can provide equipment export and technical solution customization services for overseas customers.
Contact Person: Mr. CHEN
Tel: +86 15606162805
Fax: 86-0510-8741-8884